Swing check valve
Swing check valve is a valve that can automatically prevent fluid backflow. Its valve disc automatically opens under the action of fluid pressure, and fluid flows from the inlet side to the outlet side; When the pressure on the inlet side is lower than that on the outlet side, the valve disc automatically closes under the influence of factors such as fluid pressure difference and self weight to prevent fluid backflow. Widely used in pipeline systems such as metallurgy, power plants, refineries, and petrochemical plants.
1、Main features
1.The structure is simple,the action is reliable,and the fluid resistance is lower than that of a lift check valve,making it suitable for larger caliber applications.
2.It can automatically open with the help of fluid pressure.
3.Only applicable in unidirectional media.
2、Technical specifications
1.Nominal pressure:1.6-75MPa
2.Nominal diameter:DN50-1000mm
Casting material:CF3m CF3、CF8m、CF8、CF8c、WCB、20crmov、15cr1mov、WC6、WC9
Forging materials:A105,20#,12cr1mov F22、F91、304、316、316L
3、Adopting standards
1.Design standard:GB 12236-89
2.Inspection and Testing Standards:JB/T 9092-1999
3.Structural length:GB 12221-1989
4.Flange connection size:JB79-1994
4、Main component materials,applicable media,and temperature
Part name | Material name |
Valve body, valve cover, valve disc, rocker arm, bracket | WB36 |
bolt | 35CrMo |
nut | 35CrMo |
shim | Flexible graphite+304 |
Temperature | -29~425℃ |
Applicable Medium | Water, steam, oil products, etc |
5、Storage,installation,use,and maintenance
1.Valves should be stored indoors in a relatively dry environment.
2.Valves stored for a long time should be regularly inspected for the integrity of the cover plates at both ends,cleaned of dust and dirt,and coated with anti rust oil on the valve processing surface to prevent corrosion.
3.Before installation,first check the valve markings to determine if the valve meets the requirements,then remove the cover plates at both ends and clean the valve thoroughly.
4.When closing,simply cut off the medium.
6、Possible faults and troubleshooting methods
Fault | Reason | Troubleshooting |
Leakage at the connection between the valve body and the valve cover | 1.The bolts are not tightened or have uneven tightness. on the flange surface. | 1. After the system is depressurized, tighten the bolts evenly again. and remove dirt. |
Leakage at the valve disc seal | 1. There are impurities on the sealing surface. | 1. Clean thoroughly sealing surface. |
Valve opening and closing are not flexible | 1. Wear and tear or bending deformation during uranium sales | 1. Replace and sell uranium |
Tel: 15351513006
Landline: 0515-89118577
Fax: 0515-8911 8000
Email: jtongcn 126.com
Address: Oubei Pump and Valve Industrial Park, Binhai Economic Development Zone, Jiangsu Province